Arcellor Controls (INDIA) Fine-Lok™/Well-Lok™ Tube fittings have been carefully designed and manufactured with continuous research and development backing to very stringent tolerances under rigid Quality Control procedures approved to ISO 9001-2000 quality management systems to provide zero leak, Torque free seal in instrumentation and process tubing.
Arcellor Controls (INDIA) Fine-Lok™/Well-Lok™ Tube fittings ensures maximum safety and reliability due to Tests carried out such as High pressure, impulse, vibration, vacuum, temperature, pull out and burst pressure.
Material
Arcellor Controls (INDIA) Fine-Lok™/Well-Lok™ Tube fittings are available as standard stainless steel 316. The raw materials used confirm to chemical requirements listed in specification below.
BAR STOCK
FORGING
ASME-SA – 479
ASME-SA-182 316
TYPE 316 – SS
BS970 316-S31
BS970 316 – S31
DIN 4401
DIN 4401
ASTMA276, TYPE 316
Heat Traceability
Stainless steel 316 Tube fittings are heat code traceable back to the original mill heat from which it was made.
Pressure Rating
Arcellor Controls (INDIA) Fine-Lok™/Well-Lok™ Tube fittings are rated for working pressure higher than the tubing recommended in tubing data table as shown below. However, tubing should not be used above its maximum allowed working pressure.
Tubing Selection
Stainless steel 304 and 316 fully annealed seamless tubing according to standard ASTM A213 or ASTM A269 or equivalent, are suitable for use with Fine-Lok™/Well-Lok™ Tube fittings
The tubing should be compatible with the process fluid, pressure and temperature.
For good performance of Fine-Lok™/Well-Lok™ Tube fittings, the tubing should be reasonably round, free from nicks, scratches, the surface finish should be good and tube ends are squarely cut and must be free from burrs. The hardness of tubing as desired is 80Rb; the maximum allowed by ASTM is 90Rb.
Table 1 : TUBING DATA TABLES FOR FRACTIONAL SIZE
ALLOWABLE WORKING PRESSURE (PSI)
Tubing O.D
WALL THICKNESS IN INCH
.028
.035
.049
.065
.083
.095
.109
.120
1/8
8600
10900
3/16
5500
7000
10300
1/4
4000
5100
7500
10300
5/16
4100
5900
8100
3/8
3300
4800
6600
1/2
2600
3700
5100
6700
5/8
3000
4000
5200
6100
3/4
2400
3300
4300
5000
5800
7/8
2100
2800
3600
4200
4900
1
2400
3200
3700
4200
4700
Table 2 : TUBING DATA TABLES FOR METRIC SIZE
ALLOWABLE WORKING PRESSURE (PSI)
Tubing O.D
WALL THICKNESS IN INCH
.5
.6
.7
.8
1.0
1.2
1.5
1.6
1.8
2.0
2.2
2.5
3.0
3
497
607
718
828
1032
6
331
386
497
607
774
912
8
208
280
359
440
558
607
10
221
280
342
440
473
12
182
231
280
359
386
440
497
14
195
237
302
324
369
416
463
535
654
16
169
205
361
280
319
358
398
460
564
18
150
181
230
246
280
314
349
403
496
22
121
147
185
199
225
252
280
322
394
25
108
128
162
173
196
220
244
280
342
Note : Working pressure (psig) for seamless tubing. Multiply pressure rating by 0.80 for single welded tubing. Multiply pressure rating by 0.85 for double welded tubing. Table 3 : FACTORS USED TO DETERMINE ALLOWABLE PRESSURE AT HIGHER TEMPERATURES.
°F
°C
A.I.S.I.316
200
93
1
400
204
0.96
600
316
0.85
800
427
0.79
1000
538
0.76
1200
649
0.37
For Example :The allowable pressure for type SS316, Size 1/4"OD x 0.035 wall at 600º F (316ºC) would be equivalent to 5100 psi x 0.85 = 4335 psi.
Gas Service
Extra care must be taken while selecting tubing for gas application, In order to achieve a gas-tight seal, ferrules in instruments fittings must seal any minor surface imperfections.
The thick walled tubing helps the ferrules to overcome minor surface imperfections.
Arcellor Controls (INDIA) recommends the following minimum wall thickness of tubing for gas application.
Table 4 : GAS APPLICATION TUBING (INCHES)
TUBE OD
Nominal Minimum Wall Thickness
(INCHES)
(INCHES)
1/8”
0.028”
3/16”
0.028”
1/4”
0.028”
5/16”
0.035”
3/8”
0.035”
1/2”
0.049”
5/8”
0.065”
3/4”
0.065”
7/8”
0.083”
1”
0.083”
Table 4 : GAS APPLICATION TUBING (INCHES)
TUBE OD
Nominal Minimum Wall Thickness
(METRIC)
(METRIC)
3 mm
0.8 mm
6 mm
0.8 mm
8 mm
1.0 mm
10 mm
1.0 mm
12 mm
1.0 mm
14 mm
1.2 mm
16 mm
1.5 mm
18 mm
1.5 mm
20 mm
1.8 mm
22 mm
2.0 mm
25 mm
2.2 mm
Pipe End Npt And Iso Pressure Ratings
Fitting that has both tube and pipe thread ends can have different pressure ratings. The pipe end pressure ratings chart given below for SS316 shows the pressure ratings for male and female pipe thread ends. Working pressure is calculated on ANSI code for pressure piping B31.3 basis.
Table 5 :
NPT/BSPTPIPE SIZE
WORKING PRESSURE IN PSIG
MALE THREAD
FEMALE THREAD
Straight Fittings
Shape Fittings
Straight Fittings
Shape Fittings
1/8”
9100
9100
6400
5500
1/4”
7500
7500
6600
5600
3/8”
7200
7200
5300
5000
1/2”
6600
5800
5200
4500
3/4”
6400
6400
4300
3500
1”
4600
4600
4500
3900
Table 5 : Pressure ratings are from SAE J1926/3
SAE/MS THREAD SIZE
NON POSITIONABLE
POSITIONABLE
PSIG
PSIG
5/16-24
4568
4568
7/16-20
4568
4568
1/2-20
4568
4568
9/16-18
4568
3626
3/4-16
4568
3626
7/8-14
3626
2900
1-1/16-12
3626
2900
1-3/16-12
2900
2320
1-5/16-12
2900
2320
Get in Touch